![]() ![]() The 656 page manual isn't really giving me answers. This normally works, but normally I am using the RSlogix5000. Panel View reboots and loads the program but the indicator is automatically in the error state, and will not change when I create the the Start latch memory file through the PLC program. mer file, and the panelview plus 400 on the network I will download to, and transferred. Created a runtime application (5.10 *.mer), then went to the transfer utility. Made sure to make and define 2 states on the indicator so I can see they are switching. Under my new filled folder Robot1 I selected my tag B3_1_0, Start Latch, followed by ok. Selected all tags followed by use symbol name as tag address, then selected ok. Gave a RsLinx shortcut name R1 found my RS500 file under PLC database. On the right side I right clicked and selected Import PLC tags. After selecting refresh all, I made a new folder called Robot1, and then opened that folder. Went to connections and loaded the tag browser. Added a new device shortcut called newpro1 Selected my controller on the right under Design(local) Selected apply on the top left, followed by Copy from design to runtime, followed by ok. Loaded a new FTVS file, went to RSLinx Enterprise and set up a new communications. Ensuring my controller (ML1100) is online, with my newest program. If the latter scenario, you will have to use the HMI Tag development approach, method in which the user assigns individual communications paths to all the application's "connections" CPU addresses/tags these HMI Tags are being stored within FTVS application's project tree HMI Tags folder in a similar manner to the legacy RSView/PB32/PB1400e software approach. If the former, re-configure the FTVS application Communications Settings/Design Tab path. If you could go Online with the ML controller, however, you cannot pick Online CPU tags/addresses, you either do not have a properly configured Design Communications path (Shortcut), or your CPU does not allow RSLinx Enterprise browsing. If you have properly configured the FTVS project Communications Settings/Design Tab path and the machine you are running the HMI software on could (RSLinx Enterprise) "drill down" to a subnet connected, newer generation/firmware revision MicroLogix controller, you should be able to browse the Online CPU memory addresses. Unfortunately, the MicroLogix PLCs cannot be approached in a similar manner since they are not Logix class controllers (despite the confusing product family name!). You probably have previously used FTVS to develop applications to be used on Logix (Flex-, Compact-, Control-) platforms this deployment is usually accomplished via Direct Tag Addressing (either Online with the controller, or using the CPU's Offline RSL5K application file). Your confusion is just lack of experience forget about CPU user software FTVS does not have anything to do with whatever you are using to program your controller with, RSLogix 5, 500 or 5000. ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |